User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-352CO-TRK (CO Trunk) 
10
7,
129, 
131, 
or 
133
(cont’d.)
FAIL
(cont’d.)
NOTE:
If the loop around and conference circuit test fails for 
all ports on a circuit pack, a -5 volt power problem is 
indicated. If a TN736 or TN752 power unit circuit pack 
is present, either the 631DB AC power unit or the 676B 
DC power unit may be defective. (The 631DB power 
unit is used in a medium cabinet powered by an AC 
source. The 645B power unit is used in a medium 
cabinet powered by a DC power source.) The system 
may contain a TN736 or TN752 power unit circuit pack 
or a 631DB AC power unit, but not both types of power 
units. To investigate problems with a 631DB AC power 
unit, refer to the CARR-POW (carrier port power unit for 
AC-powered systems) Maintenance documentation. 
To investigate problems with a 645B DC power unit, 
refer to the CARR-POW (carrier port power unit for 
DC-powered systems) Maintenance documentation. If 
a red LED on TN736 or TN752 power unit circuit pack 
is on, replace the pack. If the test fails on more than 1 
port, check for errors on the TONE-BD or the 
TONE-PT. If errors, take appropriate actions. When the 
tone errors are cleared, rerun the test. If the test fails 
again, see FAULT ISOLATION above.
PASS CO Trunk Loop Around and Conference Test is successful. 
User-reported troubles on this port should be investigated 
by using other port tests and by examining trunk or external 
wiring.
0NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are correct. 
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish 
the linkage between the internal ID and the port.
Table 10-97. TEST #33 Loop Around and 
Conference Circuit Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page