User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-347CO-TRK (CO Trunk) 
10
1004 ABORT The port was seized by a valid call during the test. The 
test has been aborted. Use the display port PCSSpp 
command to determine the trunk group/member number 
of the port. Use the status trunk command to determine 
the service state of the port. If the service state indicates 
that the port is in use, then the port is unavailable for 
certain tests. (Refer to the "Status Commands" section in 
Chapter 10, "Maintenance Commands and 
Trouble-Clearing Aids", for a full description of all 
possible states.) You must wait until the port is idle 
before retesting.
2000 ABORT Response to the test request was not received within the 
allowable time period.
2100 ABORT Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Any FAIL The NPE of the tested port was found to be transmitting 
in error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. 
User-reported troubles on this port should be 
investigated by using other port tests and by examining 
trunk or external wiring.
0NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should 
re-establish the linkage between the internal ID and 
the port.
Table 10-96. TEST #6 NPE Crosstalk Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page