Maintenance Object Repair Procedures 
Page 10-339CO-TRK (CO Trunk) 
10
FAIL Trunk was seized, but dial tone could not be detected.
1. Test all administered outgoing ports on the board. 
Failure of 1 indicates a problem toward the CO.
2. If all fail, see note below.
3. Check for errors on the TONE-BD or TONE-PT. Clear 
any errors found, and repeat the test.
4. If the error has still not cleared, refer the problem to 
the CO.
5. If no service problems exist on the port, continue to 
use the port until the circuit pack can be replaced 
(as a last resort). Perform a trunk test call to see if 
the trunk is operable.
NOTE:
If the dial tone test fails for all ports on a circuit 
pack, a -5 volt power problem is indicated. If a 
TN736 or TN752 power unit circuit pack is present, 
either the 631DB AC power unit or the 676B DC 
power unit may be defective. (The 631DB power 
unit is used in a medium cabinet powered by an 
AC source. The 645B power unit is used in a 
medium cabinet powered by a DC power source.) 
The system may contain a TN736 or TN752 power 
unit circuit pack or a 631DB AC power unit, but not 
both types of power units. To investigate problems 
with a 631DB AC power unit, refer to the 
CARR-POW (carrier port power unit for 
AC-powered systems) Maintenance 
documentation. To investigate problems with a 
645B DC power unit, refer to the CARR-POW 
(carrier port power unit for DC-powered systems) 
Maintenance documentation.
Table 10-94. TEST #0 Dial Tone Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page