Maintenance Object Repair Procedures 
Page 10-337CO-TRK (CO Trunk) 
10
Table 10-94. TEST #0 Dial Tone Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Could not allocate system resources to run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not 
available. The port may be busy with a valid call. Use 
the command display port PCSSpp to determine the 
trunk group/member number of the port. Use the status 
trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, 
then the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 10, "Maintenance 
Commands and Trouble-Clearing Aids", for a full 
description of all possible states.) You must wait until the 
port is idle before retesting.
1. If the port status is idle, then retry the command at 
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1001 ABORT System resources required to run this test were not 
available. This could be due to a failure to seize the port.
1. Retry the command at 1 minute intervals for a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The 
system may be under heavy traffic conditions or it may 
have time slots out-of-service due to TDM-BUS errors. 
Refer to TDM-BUS (TDM Bus) Maintenance 
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not 
handling heavy traffic, repeat test at one-minute 
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page