User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-334CO-TRK (CO Trunk) 
10
2561 57345 Single polarity ringing current. This error 
results from abnormal ringing current, 
but does not prevent the incoming call 
from being accepted. One cause could 
be that the reverse current detector 
associated with the port is failing. (Will 
not be detected by any tests.) Another 
cause could be that normal current is 
not detected. In this case, neither 
incoming nor outgoing calls can be 
completed, and the dial tone test also 
fails. The last cause could be that 
certain types of noise are present on the 
CO line during the silent period of 
ringing.
Check for other errors first 
and then see Note 4 at end of 
table.
2817 57360 Ground but no ringing. This error occurs 
on an incoming call on a ground-start 
trunk. If ringing is not detected within 5 
seconds of the Tip being grounded, the 
call is still accepted. If the CO is of the 
No. 5ESS. switch type, ringing delays of 
more than 5 seconds during heavy 
traffic are fairly common.
Check for other errors.
2817 57393 On the TN465, the loop is opening too 
slowly after a disconnect. This error 
indicates an on-board problem, 
although the trunk may be functional. 
On the TN2138, CO released the trunk 
at least 4 minutes after the PBX 
dropped the call. This error code is 
log-only and causes no other testing to 
occur. No alarm is generated.
Check for other errors.
3073 57376 No loop current on incoming call. The 
incoming destination has already 
answered and no loop current has been 
detected. If this is a hard fault, the dial 
tone test and all outgoing calls should 
also fail.
Check for other errors.
Table 10-93. CO Trunk Errors with NO Tests — Continued
Error 
Type
Aux 
Data Description and System Action System Technician Action
Continued on next page