Maintenance Object Repair Procedures 
Page 10-326CO-DS1 (DS1 CO Trunk) 
10
2000 FAIL Response to the seizure message was not received 
within the allowable time period.
1. Enter the list configuration board PCSS command. 
If the circuit pack is a TN767B vintage 8 or 9, a 
failure of test 314 causes a subsequent failure of test 
7 due to a firmware bug. Eventually, the board and 
all of its ports will be taken out of service and 
extraneous on-board alarms will be generated. 
Replace the circuit pack with a TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk 
Administration’ screen matches the trunk type 
administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware 
error log. If present, refer to the DS1-BD (DS1 trunk 
circuit pack) maintenance documentation or to the 
UDS1-BD (UDS1 trunk circuit pack) maintenance 
documentation.
4. Retry the test at 1-minute intervals for a maximum of 
5 times.
5. If the test continues to fail, escalate the problem.
2053 FAIL At least one of the following errors was found on the DS1 
circuit pack: loss of signal (1281), blue alarm (1793), red 
alarm (2049), yellow alarm (2305), or hyperactivity 
(1537).
1. Look for these error types in the hardware error log 
and then follow the procedures given in the 
maintenance documentation that is appropriate for 
the error type that was found.
PASS The trunk can be seized for an outgoing call.