Maintenance Object Repair Procedures 
Page 10-324CO-DS1 (DS1 CO Trunk) 
10
1005 ABORT Test failed due to incompatible configuration 
administered in trunk group form.
1. Verify the following fields on the trunk group 
administration screen: Is trunk direction incoming 
only? Is trunk the port 24 of the DS1 Interface circuit 
pack while common control channel signaling is 
specified? Is trunk group type the automatic CO (for 
example, FX)?
2. If the trunk has been administered using the above 
information, then this test should abort.
1018 ABORT Thest is disabled via tranlsation. You may want to 
determine why the test has been disabled before you 
enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk 
Group’ form is set to ’n’. To enable the test, issue the 
change trunk-group x command (x equals the 
number of the trunk group to be tested). Then, 
change the entry in the ’Maintenance Test’ field on 
the form to ’y’.
2. Repeat the test.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in the Hardware Error Log. If 
present, refer to DS1-BD (DS1 Trunk Circuit Pack) 
Maintenance documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
1040 ABORT The test was aborted because this port may be an 
access endpoint.
1. Verify that this port is an access endpoint by issuing 
the display port command.
2. If the port has been administered as an access 
endpoint, then this is a normal abort.
Table 10-91. TEST #314 DS1CO Dial Tone Seizure Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page