Page 10-321CO-DS1 (DS1 CO Trunk) 
10
PASS Trunk translation has been updated successfully. The 
current trunk states kept in the DS1 Interface circuit 
pack and switch software are consistent. If the trunk is 
busied out, the test does not run, but returns to PASS. To 
verify that the trunk is in-service:
1. Enter status trunk command to verify that the trunk 
is in-service. If the trunk is in-service, no further 
action is necessary. If the trunk is out-of-service, 
continue to Step 2.
2. Enter release-trunk command to put trunk back into 
in-service.
3. Retry the test command.
Table 10-90. TEST #36 Port Audit and Update Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page