Maintenance Object Repair Procedures 
Page 10-313CO-DS1 (DS1 CO Trunk) 
10
2053 ABORT At least one of the following errors was found on the DS1 
circuit pack: loss of signal (1281), blue alarm (1793), red 
alarm (2049), yellow alarm (2305), or hyperactivity 
(1537).
1. Look for the above error types in the Hardware Error 
Log and follow the procedures given in the 
appropriate DS1-BD or UDS1-BD maintenance 
documentation for the listed error types.
FAIL The NPE of the tested port was found to be transmitting 
in error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. 
User-reported troubles on this port should be 
investigated using other port tests and examining 
station, trunk, or external wiring.
Table 10-88. TEST #6 NPE Crosstalk Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page