Maintenance Object Repair Procedures 
Page 10-305CLSFY-PT (Call Classifier Port) 
10
Table 10-87. Tone Detector Audit/Update Test (#43) 
Error 
Code
Test 
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources 
needed for this test.
1. Wait one-minute, and repeat the command a 
maximum of five times.
2000 ABORT Response to the test request was not received within the 
allowable time period.
2100 ABORT Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Hardware audit failed.
1. Run the short test sequence via the test port 
PCSSpp sh r 1 command.
2. If the problem persists, the system is still operating 
properly but system capacity will be reduced. In 
order to restore system performance to normal, 
replace the CLSFY-BD (Call Classifier circuit pack) 
containing the defective CLSFY-PT (Call Classifier 
Port).
PASS The (CLSFY-PT) Call Classifier Port has passed the 
sanity inquiry.
Continued on next page