Maintenance Object Repair Procedures 
Page 10-303CLSFY-PT (Call Classifier Port) 
10
2006 ABORT This abort code indicates that the active Tone-Clock 
circuit pack might not be functioning properly. If there is 
more than one Tone Detector circuit pack in the system, 
then the problem can be either with the Tone-Clock 
circuit pack or the Tone Detector circuit pack. This could 
also be caused by the companding mode administered 
for the system not matching that of the Tone Detector 
circuit pack [G3iV2-386].
1. [G3iV2-386] Make sure that the companding mode 
of the system matches that of the Tone Detector 
(TN748 for Mu-law systems and TN420 for A-law 
systems).
2. Test the active Tone-Clock circuit pack in the port 
network. This test is being executed via the test 
tone-clock qualifier system technician command. 
("qualifier" is the carrier of the active Tone-Clock 
circuit pack to be tested. Valid qualifiers are: a, b, 
1a, 1b, 2a, and 2b.) Refer to the TONE-BD 
(Tone-Clock Circuit Pack) Maintenance 
documentation for details.
3. Retry the command at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
2000 ABORT Response to the test request was not received within the 
allowable time period.
2100 ABORT Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-86. TEST #42 Tone Detection Verification Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page