User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-280CARR-POW (Carrier Port Power Unit) for AC-Powered Systems 
10
PASS Both power units in the tested carrier were found to be 
healthy by the Maintenance/Tape Processor in Standard 
system PPN, the Duplication Interface circuit pack in a 
PPN for a system with High or Critical Reliability, or the 
EPN Maintenance circuit pack in an EPN multicarrier 
cabinet system. If the status LEDs on both power units 
are not showing green, the PR-MAINT 
(Maintenance/Tape Processor), DUPINT (Duplication 
Interface) circuit pack, or the EPN MAINT (Maintenance) 
circuit pack may have incorrectly reported the state of 
the power units. Look for and resolve any alarms on 
these MOs.
Table 10-83. TEST #127 Power Unit Query Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page