User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-278CARR-POW (Carrier Port Power Unit) for AC-Powered Systems 
10
FAIL There is a problem with one or both power units on the 
tested carrier.
1. For each power unit that has all sttus LEDs OFF, 
check the AC input to the power unit at the power 
unit outlet (see Figure 10-12 and Figure 10-13). If 
there is no AC, then check the appropriate fuses 
(see Figure 10-14) for the affected power unit. If the 
fuses are blown out, replace the fuses (see ). If the 
fuses blow out again or AC does not show up at the 
power unit outlet, then there is probably a power 
wiring problem in the cabinet. Follow normal 
escalation procedures.
2. At this point AC should be present at the power unit 
outlet. If the carrier being tested is the 1A or 2A 
carrier or the 1B carrier in a High or Critical 
Reliability system, refer to "Troubleshooting Control 
Carrier Power Units" in Chapter 5, "Routine 
Maintenance Procedures". Otherwise, use the 
recycle carrier PC command (where PC is the 
appropriate port network and carrier) in an attempt 
to bring back the power units for this carrier.
If the test passes, the trouble is cleared. If the test 
does not pass, one power unit, or both, in the tested 
carrier is defective.
If only one power unit is defective, the status LEDs 
on the healthy power unit light green for a moment. 
When the recycle test determines that both power 
units are defective, the software turns off power to 
both the good and defective power units. This 
causes the status LED(s) on the good power unit to 
light red.
3. Unplug both power units, and wait about one minute 
to allow the power units to cool down. Plug in the 
power units. If either power unit is operating properly 
(that is, the status LEDs show green), then replace 
the defective power unit(s). See "Power Unit 
Replacement Procedures" in this section.
Table 10-83. TEST #127 Power Unit Query Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page