User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-26Software Upgrade 
5
3. Select 
Reset System
 from the 
Maintenance
 menu.
4. Select 
Restart System
 from the 
Reset System
 menu.
Save Upgraded Translations onto New
Translation Card
1. Enter status system 1, and press Enter to verify the system is in “active” 
mode.
2. If the system contains a TN750/B Announcement circuit pack, check for 
completion of an automatic restore of announcements before removing 
the original translation card. If the system has been running for at least 45 
minutes since power on, this operation should be complete. Check the 
yellow LED on the TN750/B which is lit during the download. If the restore 
did not start within 15 minutes of power on, enter restore 
announcements, and press 
Enter.
3. At this point, all telephones should be working properly.
4. Insert the new Release 5.4 translation card. Verify the write switch is down.
5. The original translation card can be reformatted and reused. Enter format 
card-mem announcements and press 
Enter. This formats the original 
translation card into Release 5.4 format (even if no announcement circuit 
packs are installed).
6. Enter save translation, and press 
Enter. This instructs the system to write 
all translation information from memory onto the translation card.
7. If the system is equipped with a TN750/B Announcement circuit pack and 
announcements were restored in the above step, enter save 
announcements [‘from’ cabinet(1-X). carrier (A-D), slot (0-20)] and 
press 
Enter. Where cabinet/carrier/slot is the location of the TN750/B.
NOTE:
If multiple TN750/B circuit packs are present, you 
must
 specify the 
slot location for the save announcements command. If there is only 
one announcement circuit pack, the system defaults to the proper 
location. 
Enable TTI
If TTI was optioned prior to the software upgrade:
1. Enter change system-parameters features and press 
Enter. 
2. Use page 2 of the form to change the TTI field back to y.
Enable Scheduled Maintenance
Enter change system-parameters maintenance, and press Enter. Enable the 
scheduled daily maintenance.










