User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-202BRI-SET, ASAI-ADJ, BRI-DAT 
10
1187 ABORT The circuit pack, port or station may have been busied 
out by a technician.
1. Look in the Error Log for Error Type 18 (busied out ) 
for BRI-BD, BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then 
release the station via the release station 
command.
a. If this error type is present for BRI-PORT and 
BRI-SET, then release the port via the release 
port PCSSpp command and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and 
BRI-SET, then release the circuit pack via the 
release port PCSSpp command and run the test 
again. If the error is present for BRI-SET only, 
then release the circuit pack via the release port 
PPCSS command and run the test again. If the 
error is present for both BRI-BD and BRI-PORT, 
then release the circuit pack via the release 
board PPCSS command and run the test again.
NOTE:
When you release the circuit pack, you 
release all ports associated with it. If 
certain ports still need to be busied out, 
use the release port PCSSpp 
command to busy them out.
3. Make sure the terminal is connected.
4. Retry the command at one-minute intervals a 
maximum of five times.
5. If the test continues to abort, escalate the problem.
2012 ABORT Internal System Error.
Table 10-66. TEST #626 Signaling Link Status Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page