User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-189BRI-SET, ASAI-ADJ, BRI-DAT 
10
Hardware Error Log Entries and Test to Clear 
Values
Table 10-63. BRI-SET/ASAI-ADJ Error Log Entries 
Error Type
Aux 
Data
Associated 
Test
Alarm 
Level 
BRI-PORT
Alarm Level 
ABRI-PORT 
ATT-PORT 
LGATE-PORT
 ATTE-PT
On/ 
Off 
Board
Test to Clear 
Value
0
1
0 Any Any Any Any test BRI-SET 
or ASAI-ADJ 
ATT-ADJ 
LGATE-AJ 
ATTE-AJ
2(a) 2-10
2
None
18 0 busyout 
station ext
WARNING MAJOR/ 
WARNING
2
OFF release 
station <ext>
130(b) WRN ON test port 
PCSS sh
257(c) Any BRI Layer 3 
Query (#629)
WARNING MAJOR/ 
WARNING
2
OFF test station 
ext r 2
test 
data-module 
ext r 2
351(d) 0 None  WARNING OFF busyout and 
release station
513(e) 0 None
769(f) 0 None WARNING MAJOR OFF
2561(g) 0 None
2562- 
2566(h)
0None
2567(o) 0 None
2568(p) 0 None
2817(i) 0 XID Test 
(#628)
WARNING MAJOR/ 
WARNING
2
OFF test station 
ext r 2
test 
data-module 
ext r 2
Continued on next page