User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-130ASAI-EPT 
10
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol. 
Timers associated with certain Layer 3 messages have expired before a 
required response was received. In the following table, the aux data 
column indicates which timer has just expired. For more information, refer 
to the Lucent ISDN-BRI Specification.
The switch sent a message to an endpoint that did not respond in the 
allotted time. This may be due to failure of the point-to-point signaling link 
or because of a problem in the ASAI adjunct. To repair:
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set 
options command.
2567 (h) 0 None
2568 (i) 0 None
3329 (j) Any Signaling Link 
Status (626)
MAJ/WNG
†
OFF
3584-
3839 (k)
0, 1 None
3841 (l)
4095
0 None
Aux Data Timer Type
2 First T303 (SETUP timer)
3 Second T303 (SETUP timer)
4 T305 (DISConnect timer)
5 First T308 (RELease timer)
6 Second T308 (RELease timer)
10 T316 (RESTart timer)
12 T309 (Layer 2 Failure timer)
16 TM100 (Management Information Message timer 1)
17 TM200 (Management Information Message timer 2)
102 TASAI (ASAI Routing Timer)
Table 10-43. ASAI-EPT Error Log Entries — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level 
ASAI-EPT
On/ Off 
Board Test to Clear Value
Continued on next page