User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-125ANNOUNCE (Announce) 
10
32005 Integrated announcement circuit pack is not present. The 
Announcement Circuit Pack is not inserted, or it is defective.
1. Enter the list config command to check for the presence of the 
circuit pack in the system.
2. If the Announcement Circuit Pack is present, use the test board 
PCSS command to check the status of the Announcement 
Circuit Pack.
32006 Announcement Data Module not available.
1. Use the status command to check the status of the 
Announcement Data Module.
32007 Announcement Data Module out of service.
1. Use the status command to check the status of the 
Announcement Data Module.
32008 Announcement data is being saved or loaded.
1. Retry the command at two minute intervals a maximum of three 
times.
2. If the save/restore announcements command fails, escalate 
the problem.
32009 Required DATA-CHL is not administered or out of service. (A 
DATA-CHL is required to save or restore announcements.)
1. Add a DATA-CHL if none is administered.
2. If a DATA-CHL is administered, use the status command to 
check the status of all DATA-CHLs. At least one DATA-CHL 
should be in the in-service/idle state.
32010 
32013
DATA-CHL is not administered, or it is unavailable. (A DATA-CHL is 
required to save or restore announcements.)
1. Add a DATA-CHL if none is administered. 
2. If a DATA-CHL is administered, use the status command to 
check the status of all DATA-CHLs. At least one DATA-CHL 
should be in the in-service/idle state.
32012 Required Announcement Data Module is not administered.
1. Add an Announcement Data Module and repeat the command.
Table 10-42. Aux Data Error Codes and Recommended 
Repair Procedures  — Continued
Aux 
Data Description/ Recommendation
Continued on next page