User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-114ANN-PT (Announcement Port) 
10
Notes:
a. The Announcement circuit pack can exhibit a condition that does not allow 
recording.
If the circuit pack gets locked into this state (this is an extremely rare 
condition), two of the Announcement Ports on the circuit pack (one of 
which is the record port) will be unusable by software. Also, save/restore 
announcements will not work since the record port looks busy to the 
circuit pack. Note that software does not have any way of knowing this 
and attempts to use the ports.
If the circuit pack is locked into this state, the following symptoms are 
observed:
FAIL Test failed. Announcements played back on this port 
may sound corrupted.
1. Reset the circuit pack via the reset board PCSS 
command and then run this test again. If the test 
continues to fail, replace the circuit pack (see 
Warning).
2. If there are recurring alarms on this port caused by 
this test failing, replace the circuit pack even if Step 
1 works (see Warning).
!
WARNING:
Replacing the circuit pack results in loss of 
integrated announcements. Refer to "General 
Notes" near the beginning of this Maintenance 
procedure.
PASS This test verifies that the Angel processor can properly 
set up this port for playbacks. User-reported troubles on 
this circuit pack should be investigated using other port 
and circuit pack tests. (Refer to "ANN-BD 
(Announcement Circuit Pack)" Maintenance 
documentation for a description of the circuit pack 
tests.)
Table 10-39. TEST #205 Channel Administration Memory Array (CAMA) 
Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page