User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-111ANN-PT (Announcement Port) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
b. This error is logged and the port is alarmed when an alarm is raised on the 
Announcement circuit pack because of a faulty condition with a common 
circuit pack resource. Any one of the following alarmed errors on the 
Announcement circuit pack causes this error to be logged against the 
Announcement Port: 1793, 2049, 2305, 2561. Follow the ANN-BD 
(Announcement Circuit Pack) Maintenance documentation to resolve 
these alarms. When the corresponding circuit pack alarm is cleared, this 
alarm clears.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
Announcement Port Error Log Entries
Error 
Type
Aux 
Data Associated Test Alarm Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 Playback Speech Memory 
Array (PSMA) Test (#206)
MINOR ON test port PCSSpp sh r 3
18 0 The port was busied out WARNING OFF release port PCSSpp
130 (a) None WARNING ON test port PCSSpp sh
257 Channel Administration 
Memory Array (CAMA) 
Test (#205)
MINOR ON test port PCSSpp l r 3
17667 In-line error
513 140AY Channel Sanity 
Inquiry Test (#222)
MINOR ON test port PCSSpp sh r 3
17684 In-line error
769 (b) None