Maintenance Object Repair Procedures 
Page 10-91ANN-BD (Announcement Circuit Pack) 
10
!
WARNING:
All alarms are upgraded to MAJOR when the BASE Tone Generator is set to 
12. (France).
Notes:
a. Error Type 1
 This error indicates the circuit pack totally stopped 
functioning or it was physically removed from the system.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
1538(k) Any None MINOR ON
1793 Angel-SP 
Handshake Test 
(#208)
MINOR ON test board PCSS l r 3
17680 In-line Error
2049(l) 
(m)
Clock Match 
Inquiry Test (#212)
MINOR ON test board PCSS sh r 3
17674 In-line Error
2305 140AY Loop 
Around Test (#210)
MINOR ON test board PCSS sh r 3
2561 Super Frame 
Match Inquiry Test 
(#211)
MINOR ON test board PCSS sh r 3
17676 In-line Error
2817(l) Announcement 
Checksum Test 
(#209)
MINOR ON test board PCSS sh r 3
17682 In-line Error
17699 
(m)
In-line Error
3840(n) Any None
3999(o) Any None
Table 10-32. Announcement Circuit Pack Error Log Entries — Continued
Error 
Type
Aux 
Data Associated Test
Alarm Level (See 
WARNING 
message below)
On/Off 
Board Test to Clear Value
Continued on next page