User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-84ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
1018 ABORT The test was disabled via administration. The default for the ’Test’ field on 
the ’Station’ form is ’y’; thus, you may want to determine why this field has 
been set to ’n’ on this station (this may be due to the ringing application test 
48, which can be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station 
extension and set the ‘Test?’ field on the ‘Station Form’ to ‘y.’
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required to run this test are not available. Either a system 
allocation to get information about the port or to put the port into a service 
state failed or the attempt to put the port in connection with a tone source 
failed (this could be a tone-clock problem). The tone-clock and tone 
detectors could be having a communication problem, for example, the 
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The terminal equipment is not connected to the circuit pack or the ringing 
generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If 
present, refer to the RING-GEN (analog ring generator) Maintenance 
documentation.
3. Check all of the wiring between the station equipment and the switch. 
Then, run the test again.
4. If the test still fails, the set may be defective. Check the set, and 
replace it, if necessary.
5. Some terminal equipment (such as a modem) could fail even when it is 
connected properly. If this is the case, disable the test using the 
change station extension command (enter 'n' into the 'Test' field). 
Note that this action also disables tests 6, 7, 161, and 35 on this port.
PASS The station is connected properly to the switch. This test may also pass if 
no terminal equipment is connected and the terminal is located far from the 
switch (that is, it is off-premises). User-reported troubles on this port should 
be investigated by using other port tests, by examining station wiring, by 
examining the station, and by ensuring that the terminal is correctly 
translated as off-premises or on-premises.
NOTE:
This test always passes for TN712 Analog circuit packs prior to 
Vintage 14 and TN742 circuit packs prior to Vintage 6.
Table 10-31. TEST #48 Station Present Test — Continued
Error 
Code
Test 
Result Description/ Recommendation