User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-72ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
Battery Feed Test (also called Port Diagnostic 
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling, 
rotary dial pulsing, transmission, and balance. This test checks the signaling and 
switchhook capabilities of the battery feed chip by terminating the port, applying 
battery, and trying to detect a current.
Table 10-28. TEST #35 Battery Feed Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
1000 ABORT System resources required to run this test are not available. The port may 
be busy with a valid call. Use the display port PCSSpp command to 
determine the station extension. Use the status station command to 
determine the service state of the port. If the service state indicates that the 
port is in use, then the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 8, "Maintenance Commands and 
Trouble-Clearing Aids", for a full description of all possible states.) You 
must wait until the port is idle before retesting.
1. If the port status is idle, then retry the command at one-minute intervals 
a maximum of five times.
1004 ABORT System resources required to run this test are not available. The port may 
be busy with a valid call. Use the display port PCSSpp command to 
determine the station extension. Use the status station command to 
determine the service state of the port. If the service state indicates that the 
port is in use, then the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 8, "Maintenance Commands and 
Trouble-Clearing Aids", for a full description of all possible states.) You 
must wait until the port is idle before retesting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the 
problem.
1005 ABORT The test was aborted due to a configuration problem. This code will result 
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal 
equipment other than a voice terminal (for example, the modem pool 
member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13,14 and 15
— TN769 vintages 3,4 and 5
Continued on next page