User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-70ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required to run this test are not available. Either a 
system allocation to get information about the port or to put the port into a 
service state failed or the attempt to put the port in connection with a tone 
source failed (this could be a tone-clock problem). The tone-clock and 
tone detectors could be having a communication problem, for example, 
the companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 10-27. TEST #6 NPE Crosstalk Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page