Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN
5-85Critical Reliability
5
12. Connect the loose end of the TDM/LAN cable (between the “A” andD”
carriers) to the pin-field block markedTDM on the right side of theA”
carrier (see
Figure 5-26
and
Table 5-15
). The other end remained
connected to the “D” carrier when the old carrier was removed.
13. Connect the loose end of the TDM/LAN cable (between the “B” andC”
carriers) to the pin-field block markedTDM on the right side of theB”
carrier. The other end remained connected to the “C” carrier when the old
carrier was removed.
14. Install the TDM/LAN cable between the “A” andB” carriers. The cable is
connected to the “A” andB” carriers at the pin-field blocks marked
TDM” on the left side of each carrier.
15. On port carrier J58890BB-1, connect the TDM cable or the TDM
terminator to Slot 02. On port carriers J58890BB-2 and J58890BB-3,
connect the TDM cables or the TDM terminator to Slot 01. If the port
carrier has J58890BB-1
and
J58890BB-2 printed on it, treat it as a
J58890BB-1.
Table 5-15. TDM/LAN Connections
"J" Number Carrier Type LHS Slot RHS Slot
J58890BB-1 Port 21 02
J58890BB-2 Port 21 01
J58890BB-3 Port 21 01
J58890AF EPN Control “A” 21 02