User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-207ATM PNC-DUP (ATM PNC Duplication)
3
Error Log entries
Whenever a PNC interchange takes place, an error is logged against PNC-DUP
with a code that conveys information about the cause of the interchange and
which PNC became active. There are no alarms associated with PNC-DUP
errors, but there should be an alarm against the PNC component that caused the
interchange. There are no PNC-DUP test sequences, but
status pnc
provides
information regarding the status of the PNCs. The information in Table 3-84
and
Table 3-85
can help to identify which areas of the Alarm Log to investigate to find
the source of the problem.
Table 3-84. Error Code descriptions and Aux Data correlations
Error
Code Description Aux Data
1
1. The Aux Data indicates which PNC became active after the PNC interchange: “0” denotes PNC-A;
“1” denotes PNC-B.
00000 Error in generating error code None
1cxpp Spontaneous Interchange in response to a constraint for A-PNC Active PNC
2cxpp Spontaneous Interchange in response to a constraint for B-PNC Active PNC
51000 Spontaneous Interchange at expiration of SOH validation timer Active PNC
52000 Spontaneous Interchange upon PNC UNLOCK Active PNC
53000 Spontaneous Interchange at completion of Global Refresh Active PNC
60801 PNC Demand Interchange Active PNC
60800 PNC Demand Interchange with override Active PNC
Continued on next page