User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-100ANN-BD (Announcement Circuit Pack)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in Table 3-37 when inspecting
errors in the system. By clearing error codes associated with the
Control Channel
Loop Around Test
, for example, you may also clear errors generated from other
tests in the testing sequence.
Note:
a. For a complete description of these tests, refer to the "XXX-BD (Common
Port Circuit Pack)" Maintenance documentation.
Angel-Speech Processor (SP) Handshake Test
(#208)
This test checks the integrity of the communication link between the two
processors on the Announcement circuit pack.
!
WARNING:
Failure of this test indicates that the Speech Processor is insane and
results in the loss of all integrated announcements on the circuit pack.
Table 3-37. System Technician-Demanded Tests: ANN-BD
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
Control Channel Loop Around Test (#52) (a) X ND
Angel-Speech Processor (SP) Handshake Test
(#208)
XND
Clock Match Inquiry (#212) X X ND
Super Frame Match Inquiry (#211) X X ND
140AY Loop Around Test (#210) X X ND
Announcement Checksum Test (#209) X X ND
Network Processor Element (NPE) Audit Test
(#50) (a)
XND
SAKI Test (#53) (a) X D
Continued on next page