User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-358test network-control
2
Output
The following example shows the output from the
test network-control a
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field descriptions
Port
Port address: cabinet (always 1)-carrier-slot-circuit. For the
DATA-BD, SW-CTL, 12V-PWR, and CARD-MEM maintenance
objects, the
slot
and
circuit
fields of port address are blank.
DATA-CHL (administered data channel) uses
XX
as the slot
address and has a circuit number between 01 and 04. The carrier
field has a value
A
for the control carrier A in a simplex system.
Maintenance
Name
The name of the maintenance object
Alt. Name
Extension number of the DATA-CHL, if administered. For other
maintenance objects, this field is not applicable and, therefore,
empty.
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test network-control a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A DATA-BD 52 PASS
01A0101 DATA-CHL 4001 109 PASS
01A0101 DATA-CHL 4001 110 PASS
01A0101 DATA-CHL 4001 111 PASS
01A SW-CTL 95 PASS
01A SW-CTL 92 PASS
01A SW-CTL 94 PASS
01A SW-CTL 324 PASS
01A 12V-PWR 701 PASS
01A CARD-MEM 695 PASS
01A CARD-MEM 696 PASS
01A CARD-MEM 697 PASS
01A CARD-MEM 698 PASS
01A CARD-MEM 699 PASS
Command Successfully Completed