User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-307status system
2
BUS FAULTS
Number of faulty bus leads (defined as shorted to another lead,
stuck at some value, or an open lead: 0 - 24). This field may take on
any integer between 0 and 24. This field displays blank if:
Maintenance/Test circuit pack not present
Packet Bus port of the Maintenance/Test circuit pack has been
taken out-of-service
System does not have the Packet Bus feature
OPEN BUS
LEADS
Number of open bus leads between the Maintenance/Test circuit
pack and bus terminator (0 - 24). This could mean physical damage
to the backplane or its connectors or a missing bus terminator. This
field displays blank if:
Maintenance/Test circuit pack is not present
System does not have the Packet Bus feature.
EMERGENCY
TRANSFER
Location of the Processor or EPN Maintenance circuit pack
containing the Emergency Transfer Select Switch (
1A
and
1B
)
SELECT SWITCH
Emergency Transfer Switch position on the Processor(s) or the EPN
maintenance circuit pack and the state of Emergency Transfer in
the cabinet display:
on
: Designated analog phones in this cabinet are cut through to
CO trunk lines only in an emergency situation.
off
: Emergency Transfer is off and cannot be invoked. The
switch should only be in this state when a service technician is
on site.
auto-on
: The switch is in the or auto position, however,
because of a serious system fault, system software has invoked
Emergency Transfer.
auto-off
: Switch in the auto position; because system has no
serious faults, system software has not invoked Emergency
Tr a n s f e r
<blank> If the system is Simplex, then the 1B Emergency
Transfer indication for the PPN will display a blank. If the system
does not have an EPN, then both the 1A and 1B Emergency
Transfer indications for the EPN will display a blank.
EXP-LINK
The Expansion Link does not exist in the system; a dash (
-
)
displays.
SERVICE STATE
<blank> Expansion Interface Link does not exist
MODE
<blank> Expansion Interface Link does not exist
CABINET TYPE
CMC
(Compact Modular Cabinet)