User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-931PPP-PT (Control LAN Packet/Port)
3
Aux Data indicates the internal application number.
h.
Error Type 2305-2816
: System software detected a session is down. Aux
Data indicates the session number. These are log only errors. Error types
2305-2560 are for session numbers 1-256. Error types 2561-2816 are for
session numbers 257-512.
i.
Error Type 3329
: TCP/IP Ping Test failed.
1. Test the port (
test port UUCSSpp short
).
2. Refer to TCP/IP Ping Test (#1281) repair procedures.
j.
Error Type 3585
: TDM Port Looparound Test (#1285) failed.
1. Test the port (
test port UUCsspp long
).
2. Refer to TDM Looparound Test (#1285) repair procedure.
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate errors in the order they appear in the table below.
Error Type Application
1793 Unused
1794 DCS
1795 AUDIX
1796 CMS
1797 ISDN Gateway
1798-1920 Reserved for
future
Table 3-400. System Technician-Demanded Tests: PPP-PT
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Non-destructive
TDM Looparound Test (#1285) X D
SCOTCH Synchronous Looparound Test (#1275) X D
TCP/IP Ping Test (#1281) X X ND
Session Status Test (#1286) X X ND
PPP Link Status Test (#1279) X X ND