User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-105ATM Tips
1
These other applications may manifest themselves in the output of the
troubleshooting commands you run on the A500. DEFINITY port networks
must be identified by their A500 port numbers.
NOTE:
The following examples show DEFINITY port networks connected to A500
ports A1.1 and A1.2.
Has the A500 been installed and configured correctly?
Diagnostics
Is the A500 powered up?
If you are administering the A500 through a locally-attached console, is
there a local console terminal connected to the console port on the A500
switch processor board with the correctly-pinned RS232 serial cable?
If you are administering the A500 through telnet over the Ethernet, is there
an 10BaseT Ethernet drop plugged into the Ethernet port on the A500
switch processor board? (Note that a few A500 commands are only
permitted over the local console terminal.)
Has the A500 been booted using either the recessed reset button or by
turning the power off, then on again?
Did the A500 go through a normal power up sequence, including testing
all of the LEDs?
Are any A500 yellow fault LEDs lit?
Are the remaining A500 LEDs in a normal state (Table 1-15 above)?
Can you log into the A500 console using the diagnostic account
root
from
the local console terminal or through telnet? (See Figure 1-31
below.)