User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-670H323-BCH (H.323 B-Channel)
3
Notes:
a.
Error Type 18
: this error indicates that this specific H323 trunk group
member has been
craft
busied-out.
System Technician Commands
The following commands are available to the system technician:
busyout port UUCSSpp
this command on a specific H.323 B-channel
drops any active call that may exist on that B-channel and effectively
reduces the trunk group capacity by one. No physical piece of hardware
is removed from service.
release port UUCSSpp
this command on a specific H.323 B-channel
effectively increases the trunk group capacity by one. No physical piece
of hardware is actually added to service.
status trunk grp/mbr
this command is used to find the current status of
the specific B-channel. Additional status for an H.323 B-channel shows
near and far-end IP signaling addresses, near and far-end H.245
addresses, tunneling status, call reference value for an active call and the
H.323 conference ID.
test port UUCSSpp
this command results in the message
No tests
applicable to this object.