User's Manual

DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-90Multimedia Call Handling
1
Power Supply LEDs
Table 1-9 shows the LED and alarm conditions for the 650A Power Supply. Ring
voltage and neon bus output do not activate alarm status.
Multimedia Call Handling
‘‘Expansion Services Module’’
‘‘Troubleshooting MMCH’
Expansion Services Module
The Expansion Services Module (ESM) shown in
Figure 1-27
provides T.120 data
sharing capability on a MMCH multipoint H.320 video conference. Each
conference participant must have endpoints administered and a personal
computer with the H.320 video application installed. The DEFINITY ECS must
have the expansion service module installed.
Table 1-9. LED and Alarm Conditions
Condition LED Status Alarm State Fan Alarm
Normal Red off;
Yellow on
Open Normal
No input power Red off;
Yellow off
Closed No input power
DC output not present
(except Neon)
Red on;
Yellow off
Closed DC output not present
(except Neon)
Fan alarm Red on;
Yellow on
Closed Fan alarm