Install and Cable the Cabinets 
Page 1-49Activate and Administer the System 
1
4. If all red LEDs remain on, reseat any 
port
 circuit packs displaying red 
LEDs.
5. If the red LEDs remain on, refer to 
DEFINITY Enterprise Communications 
Server Release 6 Maintenance for Compact Modular Cabinets
.
NOTE:
Ignore the red LED on any TN767 or TN464 DS1 circuit pack until 
after it is administered. Refer to Chapter 2, ‘‘
Installation Completion 
and Cable Pinouts’’ to set the switches on these circuit packs. 
NOTE:
Alarms appear in the Alarm Log when power is applied to the 
system before all equipment connecting to port circuit packs is 
installed. Some alarms are logged when power is applied, but 
resolve quickly. If no equipment is connected to the port circuit 
packs, alarms associated with these ports can take up to 4 hours to 
log, but clear automatically after all equipment is installed and 
operating correctly.
Table 1-5. Country Codes
Country Code Country Code
USA 1 France 12
Australia 2 Germany 13
Japan 3 Czechoslovakia 14
Italy 4 Russia 15
The Netherlands 5 Argentina 16
Singapore 6 Greece 17
Mexico 7 China 18
Belgium 8 Hong Kong 19
Saudi Arabia 9 Thailand 20
United Kingdom 10 Macedonia 21
Spain 11