DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance for csi systems 
1-73Install DS1 CPE Loopback Jack (T1 Only) 
1
3. On page 2 of the form, change the 
supply CPE loopback jack 
power
 field to 
y
. 
NOTE:
Setting this field to 
y
 informs the technician that a loopback jack is 
present on the facility. This allows a technician to determine that the 
facility is available for remote testing.
4. Enter 
save translation
 to save the new information.
DS1 Span Test
This test should only be performed after the DS1 circuit pack and the 120A2 (or 
later) ICSU have been successfully tested using appropriate maintenance 
procedures. The DS1 span test consists of 2 sequential parts. Each part provides 
a result indicating if there is a problem in the CPE wiring. CPE wiring may be 
considered problem-free only if the results of both parts are successful.
The first part of the span test powers-up the loopback jack and attempts to send 
a simple code from the DS1 board, through the wiring and loopback jack, and 
back to the DS1 board. Maintenance software waits about 10 seconds for the 
loopback jack to loop, sends the indication of the test results to the management 
terminal, and proceeds to the second part of the test.
The second part of the test sends the standard DS1 3-in-24 stress testing pattern 
from the DS1 board, through the loopback jack, and back to a bit error detector 
and counter on the DS1 board. The bit error rate counter may be examined at will 
via the management terminal, and provides the results of the second part of the 
test. The test remains in this state until it is terminated so that the CPE wiring may 
be bit error rate tested for as long as desired.
1. Busy out the DS1 circuit pack by entering 
busyout board UUCCSS
(where UUCCSS is the cabinet, carrier, and slot number of the DS1 
board).
2. At the management terminal, enter 
change ds1 <location>
 and verify the 
near-end csu type
 is set to 
integrated
.
3. Change to page 2 of the DS1 administration form and confirm that the TX 
LBO field is 0dB. If not, record the current value and change it to 0dB for 
testing. Press 
Enter to implement the changes or press Cancel to change 
nothing.