DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-422DATA-BD (Data Channel Processor Circuit Pack) 
3
be completely normal during heavy traffic periods. However, if this error 
type is logged when the circuit pack is being lightly used, it may indicate a 
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
NPE Audit Test
, for example, you may also clear 
errors generated from other tests in the testing sequence.
Note:
a. Refer to “DATA-CHL” and “SW-CTL” for other tests associated with 
DATA-BD maintenance.
NPE Audit Test (#50)
The system sends a message to the on-board microprocessor to update the 
network connectivity information for all the NPEs on the circuit pack.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Audit Test (#50) (a) X ND
Control Channel Loop Around Test (#52) X X ND
Table 3-181. TEST #50 NPE Audit Test 
Error 
Code
Te s t 
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
2100 ABORT Could not allocate the necessary system resources to run this test.
1019 ABORT Test already in progress.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The circuit pack’s NPEs have been updated with their translation.
Continued on next page