User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-415CONFIG (System Configuration) 
3
CONFIG (System Configuration)
The System Configuration maintenance object (MO) oversees logical insertion 
and removal of circuit packs in the system. When Switch Control detects that a 
circuit pack is present in a port slot, it informs System Configuration and System 
Configuration queries the circuit pack to determine the type and vintage of the 
circuit pack. Similarly, when Switch Control detects that a circuit pack has been 
removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors 
are logged to the Hardware Error Log (see below).
Hardware Error Log Entries and Test to Clear 
Valu es
Notes:
a. This error indicates that a Port circuit pack in the system did not respond 
to a circuit pack type inquiry. Follow the procedures outlined in (c) to 
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a Port circuit pack in the system did not respond 
to a vintage inquiry.
As a result of either of these errors, a Port circuit pack may be physically 
inserted in a Port slot, but the system may not recognize it. 
MO Name (in 
Alarm Log)
Alarm 
Level Initial Command to Run Full Name of MO
CONFIG none none System Configuration
Error Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0 Any Any Any none
2-117(a) 0-2 none
257(b) none
1002-1117(c) 0-2 none