User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-410CO-TRK (CO Trunk) 
3
Transmission Test (#844-848)
This test is non-destructive.
NOTE:
Tests #844-848 are not supported on a International switch.
These tests are run by the Automatic Transmission Measurement System (ATMS). 
They are not part of the long or short trunk test sequences. Instead, they are run 
on demand with the 
test analog-testcall
 command or as part of ATMS 
scheduled testing.
The test call attempts to seize a port and make a call to a terminating test line 
(TTL) on the trunk’s far end. Transmission performance measurements are made 
and compared to administered thresholds. Errors are generated when results fall 
outside of ‘‘marginal’’ or ‘‘unacceptable’’ thresholds. Detail and summary 
measurement reports are obtainable via the 
list testcalls
 command.
0NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the 
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage 
between the internal ID and the port.
Table 3-177. TEST #36 Port Audit Update Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page