Table 3-175. TEST #6 NPE Crosstalk Test 
Error 
Code
Te s t 
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT The port was seized by a user for a valid call. Use the display port 
PCSSpp command to determine the trunk group/member number of the 
port. Use the status trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, then the port is 
unavailable for certain tests. You must wait until the port is idle before 
retesting.
1. If the port status is active but the port is not in use (no calls), check the 
error log for error type 1025 (see the Error Log table for a description 
of this error and required actions). The port may be locked up. Check 
the CO wiring, check for excessive loop current, and check the trunk 
translations. (If the trunk is translated incorrectly, this test will abort.)
2. If the port status is idle, busyout and release the trunk, and then retry 
the command at 1-minute intervals for a maximum of 5 times.
3. If the test still aborts, replace the circuit pack.
1001 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS (TDM-Bus) Maintenance 
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of tone detectors present or some tone 
detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV 
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT 
Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a 
maximum of 5 times.
Continued on next page