User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-377CO-DS1 (DS1 CO Trunk) 
3
Table 3-167. TEST #6 NPE Crosstalk Test 
Error 
Code
Te s t 
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a maximum of five times.
1000 ABORT System resources required to run this test were not available. The port may 
be busy with a valid call. Use the display port PCSSpp command to 
determine the trunk group/member number of the port. Use the status 
trunk command to determine the service state of the port. If the service 
state indicates that the port is in use, then the port is unavailable for certain 
tests. You must wait until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the 
error log for error type 1025 (see the error log table for a description of 
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals for a 
maximum of 5 times.
1001 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to the TDM-BUS (TDM Bus) Maintenance 
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at one-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some tone 
detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV 
(TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT 
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a 
maximum of 5 times.
1004 ABORT The port was seized by a user for a valid call. Use the display port 
PCSSpp command to determine the trunk group/member number of the 
port. Use the status trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, then the port is 
unavailable for certain tests. You must wait until the port is idle before 
retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a 
maximum of 5 times.
Continued on next page