Maintenance Objects 
3-371CLSFY-PT (Call Classifier Port) 
3
FAIL Hardware audit failed.
1. Run the short test sequence via the test port PCSSpp sh r 1 
command.
2. If the problem persists, the system is still operating properly but 
system capacity will be reduced. In order to restore system 
performance to normal, replace the CLSFY-BD (Call Classifier circuit 
pack) containing the defective CLSFY-PT (Call Classifier Port).
PASS The (CLSFY-PT) Call Classifier Port has passed the sanity inquiry.
Table 3-165. Tone Detector Audit/Update Test (#43) — Continued
Error 
Code
Te s t 
Result Description/ Recommendation