Maintenance Objects 
3-369CLSFY-PT (Call Classifier Port) 
3
1002 ABORT The system could not allocate time slots for the test connection. This 
situation could occur when the system is heavily loaded. If the system is 
not heavily loaded, then test the TDM-BUS via the test tdm [1|2] 
command. Refer to the TDM-BUS (TDM Bus) Maintenance documentation 
for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a Tone-Clock circuit pack for the test 
connection. This situation could occur when the system is heavily loaded 
or if a Tone-Clock circuit pack is not present in the port network when this 
test is executed.
1. Verify the existence of a Tone-Clock circuit pack in the same port 
network.
2. If a Tone-Clock circuit pack is missing, install one in the same port 
network.
3. Allow approximately 1 minute for the Tone-Clock circuit pack 
maintenance to run on the newly inserted Tone-Clock circuit pack.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2006 ABORT This abort code indicates that the active Tone-Clock circuit pack might not 
be functioning properly. If there is more than one Tone Detector circuit 
pack in the system, then the problem can be either with the Tone-Clock 
circuit pack or the Tone Detector circuit pack. This could also be caused 
by the companding mode administered for the system not matching that of 
the Tone Detector circuit pack.
1. Make sure that the companding mode of the system matches that of 
the Tone Detector (TN748 for mu-law systems and TN420 for A-law 
systems).
2. Test the active Tone-Clock circuit pack in the port network. This test is 
being executed via the test tone-clock qualifier system technician 
command. ("qualifier" is the carrier of the active Tone-Clock circuit 
pack to be tested. Valid qualifiers are: a, b, 1a, 1b, 2a, and 2b.) Refer 
to the ‘‘TONE-BD (Tone-Clock Circuit Pack)’’
 Maintenance 
documentation for details.
3. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-164. TEST #42 Tone Detection Verification Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page