User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-353CLAN-BD (Control LAN Circuit Pack) 
3
1. Busyout (
busyout board UUCSS
) and release (
release board 
UUCSS
) circuit pack
2. Allow 30 minutes for condition to clear itself.
3. To re-establish circuit pack into service manually, busyout (
busyout 
board UUCSS
), reset (
reset board UUCSS
), and release (
release 
board UUCSS
) the circuit pack.
4. If error recurs within 15 minutes, replace the circuit pack. 
5. If the same error occurs on a different circuit pack, follow normal 
escalation procedures.
r.
Error Type 3840
: Circuit pack received bad control channel message 
from switch.
Aux Data:
s.
Error Type 3841-3843
: errors do not affect service.
Below, Error Types correspond to descriptions.
If Error Type 3999:
And traffic 
volume is: Then:
Does not accompany 
Error Type 3586,
Heavy Circuit pack is in service, but 
sent at least half hyperactive 
threshold. With heavy traffic, this 
is normal.
Does not accompany 
Error Type 3586,
Light Circuit pack is in service, but 
sent at least half hyperactive 
threshold. With light traffic, this 
error indicates a problem with the 
circuit pack, its links, or the 
equipment attached to the links.
Accompanies Error 
Type 3586,
Either Light or 
Heavy
Switch removed hyperactive 
circuit pack.
4096 Bad major heading
4097 Bad port number
4098 Bad data
4099 Bad sub-qualifier
4100 State inconsistency
4101 Bad logical link
4102 Bad application identifier
3841 Internal firmware error.
3843 Bad translation RAM. Call uses another translation location.