User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-268BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
3
BRI-PORT (ISDN-BRI Port),
ABRI-PORT (ASAI ISDN-BRI Port)
NOTE:
Some of the information in this section is reserved for future use.
!
WARNING:
If a significant Packet Bus failure occurs, errors and alarms may not be 
logged as expected for 
BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT. 
The TN2208 LGATE MFB provides DEFINITY with the interface to Adjunct-Switch 
Application Interface (ASAI) and Lucent adjuncts (for example, CONVERSANT
®
. 
Voice System). The circuit pack contains 12 ports of line circuit interface 
(although only 8 are usable by the switch), each of which operates with two 
B-channels (referred to as B1 and B2 throughout this section) and one D-channel 
MO Name (in 
Alarm Log) Alarm Level
Initial Command to 
Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (A, B, or C); and 
SS is the address of the slot in the carrier where the circuit pack is located (01, 02, ..., etc.); 
and pp is the 2-digit port number (for example, 01).
Full Name of MO
BRI-PORT MINOR test port PCSSpp l ISDN-BRI Port
BRI-PORT WARNING test port PCSSpp sh ISDN-BRI Port
ABRI-PORT MAJOR
2
,
3
2. The alarm level for ASAI and Lucent adjunct ports may be administered using the set 
options command. The alarm level can be set independently for Off-Board and On-Board 
alarms to WARNING, MINOR, or MAJOR for all ASAI and Lucent adjunct ports in the system.
3. All alarming for an ASAI and Lucent adjunct and OFF-BOARD alarming for an ASAI or Lucent 
port is disabled if the ASAI or Lucent adjunct asks the switch to suspend maintenance. When 
this occurs, an error and a WARNING alarm is logged against the ASAI or Lucent adjunct. 
The Hardware Error and Alarm Logs should be checked to see if the adjunct has disabled 
alarming.
test port PCSSpp l ASAI ISDN-BRI Port
ABRI-PORT WARNING
2
,
3
test port PCSSpp l ASAI ISDN-BRI Port
ATT-PORT MAJOR
2
, 
3
test port PCSSpp l Lucent Adjunct ISDN-BRI Port
ATT-PORT WARNING
2
, 
3
test port PCSSpp l Lucent Adjunct ISDN-BRI Port
LGATE-PORT MAJOR
2
, 
3
test port PCSSpp l Ethernet ASAI Port
LGATE-PORT WARNING
2
, 
3
test port PCSSpp l Ethernet ASAI Port
ATTE-PT MAJOR
2
, 
3
test port PCSSpp l Ethernet Lucent Adjunct Port
ATTE-PT WARNING
2
, 
3
test port PCSSpp l Ethernet Lucent Adjunct Port