There are no tests associated with these MOs. Both the 
test board
 and 
busy out 
board
 commands abort when either is attempted on a reserved slot. An error 
message indicates that the slot is associated with the circuit pack that the TN568 
is emulating, but the requested operation is not valid. If there are errors logged 
against these maintenance objects, see XXX-BD.
The TN568 circuit pack connects to the switch through a single slot in the 
backplane; however, the number of slots physically occupied by the circuit pack 
is supplied by the board when inserted. The TN568 is 2 slots wide: the functional 
slot and a reserve slot. The reserve (blank) slot to the left of the functional slot is a 
place holder on the switch and has no interaction with the switch.
These MOs are place holders for the extra slot needed for the DEFINITY AUDIX 
board. Each instance of these MOs represents a reserve slot associated with the 
respective circuit pack mode in which the TN568 (DEFINITY AUDIX) is working. 
They are used for embedded AUDIX and emulation of respective port types.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run Full Name of MO
AXA12-RS NONE NONE TN568 12-port analog 
reserve slot
ADX8D-RS NONE NONE TN568 8-port digital reserve 
slot
AXD12-RS NONE NONE TN568 12-port digital 
reserve slot