User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-75AN-LN-PT (Analog Line Port) 
3
System technician-demanded tests: descriptions 
and error codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Battery Feed Test,
 for example, you may also clear errors generated from other 
tests in the testing sequence.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Battery Feed Test (#35) X X ND
Station Present Test (#48) X X ND
Looparound Test (#161) X ND
Conference Test (#7) X ND
NPE Crosstalk Test (#6) X ND
Station Status and Translation Audits and 
Updates Test (#36)
XXND