3-63ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
3
1 FAIL This does not indicate a hardware problem. The switchhook audit failed, 
and the other updates were not performed because of this failure. This 
condition may occur when the audit is performed at the same time that the 
terminal equipment goes off-hook. Use the status station command to 
determine when the port is available for testing.
1. When the port becomes available for testing, retry the command at 
1-minute intervals a maximum of 5 times.
5 FAIL This does not indicate a hardware problem but may indicate an internal 
software error. The message waiting lamp update failed. The translation 
and ringer updates were not performed because of this failure.
7 FAIL The translation update failed. The ringer update was not performed 
because of this failure. This does not indicate a hardware problem but may 
be an internal software error.
8 FAIL This does not indicate a hardware problem but may be an internal software 
error. The ringer update failed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The software and the port processor have the same status. User-reported 
troubles on this port should be investigated by using other port tests, by 
examining station wiring, by examining the station, and by ensuring that the 
terminal is correctly translated as off-premises or on-premises. 
NOTE:
This test always passes for TN742 Analog circuit packs prior to 
Vintage 6.
0NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list 
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.