Maintenance Objects 
3-57ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
3
1018 ABORT Test disabled via administration. The default for the ’Test’ field on the 
’Station’ form is ’y’; thus, you may want to determine why this field has 
been set to ’n’ on this station (this may be due to the ringing application 
test 48, which can be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station 
extension and set the ‘Test?’ field on the ‘Station Form’ to ‘y.’
1020 ABORT The test did not run due to a previously existing error on the specific port 
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required to run this test are not available. Either a 
system allocation to get information about the port or to put the port into a 
service state failed or the attempt to put the port in connection with a tone 
source failed (this could be a tone-clock problem). The tone-clock and 
tone detectors could be having a communication problem, for example, 
the companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL This test can fail due to on-board or off-board problems. Off-board 
problems of concern include EXP-INTF faults, TDM-BUS faults, and faults 
associated with the tone detectors/tone generators. Clear all off-board 
problems before replacing the board. Keep in mind that a TDM-BUS 
problem is usually the result of a faulty board connected to the backplane 
or bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer to the 
EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the 
TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the error log. If present, 
refer to the TONE-BD Maintenance documentation and the TONE-PT 
Maintenance documentation.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. 
Replace the board only if the test fails.
Table 3-24. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page