DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-39ANL-24-L (24-Port Analog Line) 
3
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or have time slots out-of-service due to 
TDM-BUS errors. Refer to “TDM-BUS” to diagnose any active TDM-BUS 
errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of tone detectors present or some tone 
detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to “TTR-LEV”.
2. Look for TONE-PT errors in the Error Log. If present, refer to 
“TONE-PT”.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been 
aborted. Use the display port PCSSpp command to determine the station 
extension. Use the status station command to determine the service state 
of the port. If the port is in use, wait until the port is idle before testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test may not be 
applicable, or it may be disruptive to terminal equipment other than a voice 
terminal (for example, the modem pool member or Music On Hold).
1018 ABORT The test has been disabled by administration. The default for the Test field 
on the station form is y. Determine why this field has been set to n on this 
station (this may be due to the ringing application test 48, that can be 
customer or terminal disturbing).
1. To enable the test for a particular station being tested, enter change 
station extension and set the Test? field on the station from n to y.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required to run test are not available. This could be due 
to a failure to seize the port. 
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-16. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Te s t 
Result
Description/Recommendation
Continued on next page