User manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-22ADX16D-P (16-Port AUDIX Digital Port) 
3
■ Station Lamp Updates Test (#16)
■ Station (Digital) Audits Test (#17)
■ Digital Terminal Remote Loop Around Test (1201)
NPE Crosstalk Test (#9)
This test verifies that this port’s NPE channel talks on the selected time slot and 
that it never crosses over to time slots reserved for other connections. If the NPE 
is not working correctly, one-way and noisy connections may be observed. This 
test is part of a port’s Long Test Sequence, and it takes about 20 to 30 seconds to 
complete. 
Crosstalk testing is performed on both the primary information channel (voice) 
and on the secondary information channel (data) associated with each DEFINITY 
AUDIX port. If this test fails on either channel, the voice port is taken 
out-of-service.
Table 3-9. TEST #9 NPE Crosstalk Test 
Error 
Code
Te s t 
Result Description/Recommendation
1 ABORT During testing of the primary information channel, system resources may 
not have been available. Also, the port may have been busy during the 
test.
1. Check the port status. Use the display port PCSSpp command to 
determine the voice port extension of the port. Use the status station 
command to determine the service state of the port. If the port is in 
use, it is unavailable for this test. Wait until the port is idle.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2 ABORT System resources may not have been available, or the port may have been 
busy during the test.
1. Check if port is being used, retry the command at 1-minute intervals a 
maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may 
be in use. Use the display port PCSSpp command to determine the voice 
port extension of the port. Use the status station command to determine 
the service state of the port. If the port is in use, it is unavailable for certain 
tests. Refer to “Status” commands in Chapter 8, "Maintenance Commands 
and Trouble-Clearing Aids", for a full description of all possible states. Wait 
until the port is idle before testing.
1. If the port status is idle, retry the command at 1-minute intervals a 
maximum of 5 times.
Continued on next page